de/LipoSaver








Info

The LipoSaver is used for lipo monitoring for 3 or 4-cell lipos.

The lipo can be connected either directly or via balancer input.

INFO:
If a connected consumer requires too high inrush current, the LipoSaver can switch off the output directly due to the temporarily low voltage !








Technical data


http://gallery3.mikrokopter.de/var/albums/intern/MK-Baugruppen/LipoSaver/LipoSaverDimension.jpg?m=1558440906

  • Dimensions: 33 x 16mm
  • Voltage: 3S (11,1V) or 4S (14,8V)
  • Internal power consumption: ca. 3mA
  • max. current: ca. 1A
    (without reverse polarity protection ~5A)


  • Voltage ranges = 4S Lipo

    • Warnung Summer - ~13,2V
    • Shutdown - ~12,3V
  • Voltage ranges = 3S Lipo

    • Warnung Summer - ~10,6V
    • Shutdown - ~9,5V






Connection 4S Lipo

http://gallery3.mikrokopter.de/var/albums/intern/MK-Baugruppen/LipoSaver/LipoSaver-4S-Balancer.jpg?m=1558440926


If the supplied 5-pin header is soldered to the ! LipoSaver, a 4S Lipo can be plugged directly over the balancer connector.





http://gallery3.mikrokopter.de/var/albums/intern/MK-Baugruppen/LipoSaver/LipoSaver-4S-Direkt.jpg?m=1558440927


Optionally, the connection can also be soldered directly to the Plus (+) and GND (-) pads.








Connection 3S Lipo

http://gallery3.mikrokopter.de/var/albums/intern/MK-Baugruppen/LipoSaver/LipoSaver-3S-Balancer.jpg?m=1558442972

If the supplied header is soldered to the ! LipoSaver, a 3S Lipo can be plugged directly over the balancer connector.

IMPORTANT

  • The upper pin of the pin header must be removed to avoid causing a short circuit!

  • There must be a solder bridge between:
    • the upper Plus (+) pad and the underlying pad

    • the 3S pads on the other side of the board



http://gallery3.mikrokopter.de/var/albums/intern/MK-Baugruppen/LipoSaver/LipoSaver-3S-Direkt.jpg?m=1558440907

Optionally, the connection can also be soldered directly to the Plus (+) and GND (-) pads.

IMPORTANT

  • There must be a solder bridge between the 3S pads on the other side of the board








Current

http://gallery3.mikrokopter.de/var/albums/intern/MK-Baugruppen/LipoSaver/LipoSaver1A-5A.jpg?m=1558440905

On the LipoSaver is a diode as reverse polarity protection. With this diode the max. Current drain is limited to ~1A.

If you remove this diode and replace it with a solder bridge, a max. Current consumption up to 5A can be used.

BUT BEWARE: This eliminates the reverse polarity protection!